To load a patch file
1. Configure the LOADER.
Set the LOADER module with defaults to make the process of
downloading files in future simpler.
SET LOADER METHOD=HTTP SERVER=192.168.1.1
DESTINATION=FLASH
2. Download the patch file.
Download the patch file onto the switch, using the defaults set above.
LOAD FILE=86251-01.paz
When the download has completed, check that the file is in FLASH.
SHOW FILE
This shows the file 86251-01.paz is present.
To activate the patch see “To upgrade to a new patch file:” on page 60.
Uploading Files From the Switch
The LOADER can upload files from the switch to a network host, using TFTP
or ZMODEM. Upload files using one of the commands:
UPLOAD [METHOD=TFTP] [FILE=filename]
[SERVER={hostname|ipadd}]
UPLOAD [METHOD=ZMODEM] [FILE=filename] [ASYN=port]
The UPLOAD command uses defaults set with the SET LOADER command,
for parameters not specified with the upload command.
You can install Allied Telesyn’s Trivial File Transfer Protocol Server (AT-TFTP
Server) on any PC or server running Windows. This will provide a simple way
to make files available to all Allied Telesyn routers and layer 3 switches in your
network. The TFTP Server, and a readme file describing how to install and use
it, are provided on the Rapier Series Switch Documentation and Tools CD-ROM.
Example: Upload a Configuration File Using TFTP
This example uploads a configuration file from the switch to a TFTP server on
the network. Before following this procedure, make sure:
The TFTP server is operating on a host with an IP address (for example
192.168.1.3) on the network.
The switch has a valid IP address (for example 192.168.1.2) on the interface
connecting it to the TFTP server, and that it can communicate with the
server.
The configuration file is present in the router’s FLASH.
To upload a log file:
1. Configure the LOADER.
Set the LOADER module with defaults to make the process of
downloading and uploading files in future simpler.
SET LOADER METHOD=TFTP SERVER=192.168.1.3