Introduction Logging Procedures
Software Reference for SwitchBlade x3100 Series Switches (Setting Up the Switch)
1-178
SET LOG OUTPUT
Syntax
SET LOG OUTPUT=outputid
[ { CLI [ FORMAT={ FULL | MSGONLY | SUMMARY } ] |
CONSOLE [ FORMAT={ FULL | MSGONLY | SUMMARY } ] |
SYSLOG { [ SERVER={ ipaddress | hostname } ] }
{ [ FACILITY={ 0..7 | DEFAULT } ] |
[ CRITICALFACILITY={ 0..7 | DEFAULT } ]
[ MAJORFACILITY={ 0..7 | DEFAULT } ]
[ MINORFACILITY={ 0..7 | DEFAULT } ]
[ INFOFACILITY={ 0..7 | DEFAULT } ] } |
FILE=unit:filename [ FORMAT={ FULL | MSGONLY | SUMMARY } ] } ]
Description Used to change the management log output destination settings. By default, if no cate-
gory, severity or format options are specified, the management log filter is set to match
all logs.
Options The following table gives the range of values for each option that can be specified with
this command and a default value (if applicable).
Option Description Default Value
OUTPUT The outputid that was created.
CLI The output will go to the Command Console.
FORMAT can be:
- FULL displays the entire log message.
- SUMMARY displays only the category, timestamp, and
log type.
- MSGONLY displays only the log message.
CONSOLE The FORMAT meanings are the same as for the CLI.
SYSLOG
SERVER
The SERVER that will receive the management log
stream
FACILITY The log facility that all levels of syslogs are sent to.
Refer to RFC3164 for details on the SYSLOG protocol.
2 (DEFAULT)
CRITICAL-
FACILITY
The log facility that critical syslogs are sent to. The pos-
sible values are 0-7, indicating LOCAL0-LOCAL7 or
DEFAULT.
LOCAL2
MAJORFA-
CILITY
The log facility that major syslogs are sent to. The pos-
sible values are 0-7, indicating LOCAL0-LOCAL7 or
DEFAULT.
LOCAL2