Specifications
50Alvium G1 User Guide V1.7.0
Cameras were inspected before and after the tests. All tests were passed
successfully:
The conditions for cameras and lenses were the same for all tests. Solid aluminum
tubes were used to represent real lenses:
IEC 60068-2-6: Sinusoidal vibration
Condition Passed
Mechanics • The camera housings showed no deformations.
• The connections between camera components had not come loose.
• The sensor position was within the specified tolerances of a new camera.
Camera behavior Camera functionalities were not affected, no deviations occurred.
Image streaming Images were streamed without errors.
Table 9: Conditions for passed tests
Parameter Value
Lens dummy length 22 mm
Lens dummy mass 70 g
Center of gravity (CoG)
1
17 mm
1
For camera and lens dummy assemblies, measured from the lens mount front flange
Table 10: Conditions for lenses
Frequency Acceleration Displacement
10 Hz to 58.1 Hz Not applicable 1.5 mm
58.1 Hz to 500 Hz 20 g Not applicable
Table 11: Frequency, acceleration, and displacement for IEC 60068-2-6 tests
Parameter Value
Axis
1
x, y, z
Sweep rate 1 oct/min
Sweep duration per axis [hh:mm:ss] 03:45:40
Number of sweeps 10
1
For technical reasons, all three axes are tested with the shaker in the upright position without a sliding
table.
Table 12: Other parameters for IEC 60068-2-6 tests