6-1622176 rev.05 01/03/2019
Compatible from firmware version BIOS2ECOv07
6.1 Base settings menu:
MENU DESCRIPTION
SELECTABLE
VALUES
min-max
DEFAULT UNITS
tCL
tCLtCL
tCL
Auto reclosing time (0 = disabled) 0-900 0 s
ttr
ttrttr
ttr
Auto reclosing time after transit(0 = disabled) 0-30 0 s
Trq
Trq Trq
Trq
Motor torque (running torque) 10-100 100 %
SSL
SSLSSL
SSL
Slowing down mode
0 = normal
1 = fast with more torque
0-1
1
SbS
SbSSbS
SbS
Step by step configuration
0 = normal (OP-ST-CL-ST-OP-ST…)
1 = alternated STOP (OP-ST-CL-OP-ST-CL…)
2 = alternated (OP-CL-OP-CL…)
3 = condominium – timer
4 = condominium with immediate auto reclosing
0-4 0
SSt
SStSSt
SSt
Soft start
0 = disabled
1 = enabled
0-1 0
DLY
DLYDLY
DLY
Second wing delay 0-300 2 s
LsI
LsILsI
LsI
Amplitude of slowing down (0 = disabled)
P = personalized during learning
0…100% = percentage of stroke
0-100 15 %
ASL
ASLASL
ASL
Anti slip 0-300 0 s
nmt
nmtnmt
nmt
Number of motors
1 = 1 motor
2 = 2 motors
1-2 2
6. Menu
Entering the menu:
To enter the base menu settings keep pressed the MENU button for at least one second
To enter the advanced menu settings keep pressed the MENU button for at least five seconds
Navigation into the menu:
It is possible to move from an entry to another one using UP[+] e DOWN[-] buttons,
To change a parameter keep pressed the MENU button for at least 1 second until the parameter begins blinking,
so release the key.
Use UP[+] and DOWN[-] buttons to change the parameter
At the end keep pressed MENU for al least 1 second until the parameter stops blinking to save the change.
A quick pressure of the menu key is enough to leave a menu
Ex. Base menu
Ex. Advanced menu

Related product manuals