6.2 Advanced menu:
MENU DESCRIPTION
SELECTABLE
VALUES
min-max
DEFAULT UNITS
LP
LPLP
LP
.
o
oo
o
.
Partial opening 0-100 30 %
tP
tPtP
tP
.
r
rr
r
.
Pre-flashing time (0 = disabled) 0-10 0 s
FC
FCFC
FC
.
Y
YY
Y
.
Courtesy ligth settings
0 = At the end of movement for a TCY time
1 = Open gate light on/off
0-1 0
tC
tCtC
tC
.
Y
YY
Y
.
Courtesy light time 0-900 180 s
dE
dEdE
dE
.
A
AA
A
.
Dead-man
0 = disabled
1 = enabled
0-1 0
HA
HAHA
HA
.
o
oo
o
.
Water-hammer in opening phase (0 = disabled) 0-100 0
x100
ms
HA
HAHA
HA
.
c
cc
c
.
Water-hammer in closing phase (0 = disabled) 0-100 0
x100
ms
MP
MPMP
MP
.
r
rr
r
.
Time of pressure in closed for hydraulic motors (0 = disabled) 0-480 0 minuti
dE
dEdE
dE
.
F
FF
F
.
Restore default settings, enter to modify the parameter and then keep pressed the
MENU button, a count down appears that ends with don on the display
tr
trtr
tr
.
F
FF
F
.
Cancelling all transmitters, enter to modify the parameter and then keep pressed
the MENU button, a count down appears that ends with don on the display
Cancellation of a single transmitter 0-999
Viewing of the memory location for a single transmitter 0-999
Electrical lock mode
0 = disabled
1 = Active Electrical lock without preventive activation
2 = Active Electrical lock with preventive activation
3 = Magnetic Electrical Lock
0-3 0