EasyManua.ls Logo

Allmatic TRAKTOR /I Series - Menu of Advanced Functions

Allmatic TRAKTOR /I Series
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38 - English - Translated from the original language Manual 6-1624970M - rev. 1 - 11/01/2023
5.8 - MENU OF ADVANCED FUNCTIONS
To access the advanced features menu, press and hold the MENU button for longer than 5 seconds.
Use the UP and DOWN buttons to scroll through the available features.
While displaying a function, the control unit will alternate the display of the item to the value set in it.
To change the value of the parameter you are viewing proceed as follows:
Press and hold the MENU button for at least 3 seconds, the currently set value flashes.
Use the UP and DOWN buttons to select the desired value.
Confirm the value by holding down the MENU button for at least 3 seconds.
To exit, press the MENU button quickly.
NOTE
• The values in this chapter refer to the configuration with advanced parameter DEF = 0
PARAMETER LIST
Mode of intervention of the impact sensor
NOTE
• Adjust this parameter according to current regulations.
Determines which areas of the stroke the impact sensor is active.
PARAMETER VALUES DEFAULT
SnM
OFF = Disabled.
1 = Normal and slowdown areas.
2 = Only normal speed area.
3 = Only slowdown speed area.
2 = Only normal speed area.
Intervention time of the impact sensor
It determines how long the impact sensor takes after the obstacle has been reached (motor blocked).
PARAMETER VALUES DEFAULT
Sit
From 1 to 10 multiplied by 100 ms 2 = 200 ms
Time to disable impact sensor at movement begin
Determines how long the impact sensor is disabled at the start of handling.
PARAMETER VALUES DEFAULT
Sdt
From 1 to 30 multiplied by 100 ms 15 = 1500 ms
Mode of intervention PH1 photocell input
During the closing movement the engagement of the connected photocell on the input PH1 always involves the reversal of the mo-
tion and consequent handling up to the position of "OPEN GATE".
Moreover, during the opening movement, the photocell input does not cause any intervention of the control unit.
With this parameter it is possible to customize the behavior of the control unit following the intervention of the photocell, in case the
automation is stopped in the position of "CLOSED GATE".
Value 0: The automation doesn't start if the PH1 input is engaged.
Valore 1: The automation moves in opening even if the PH1 input is engaged.