6. ERROR MESSAGES
DISPLAY DESCRIPTION SOLUTION
ELS
Limit switch error: Opening and closing limit
switches occupied simultaneously, or locked.
• Check that the limit switch is not blocked.
• Check electrical connections and limit switch
integrity.
• Check the integrity of the fuses.
EFO
Movement stopped by the impact sensor. Eort too
high to allow movement of the gate.
• Check the integrity and good condition of the
entire gate and automation.
• Remove any dirt or foreign matter that may
hinder movement.
• Adjust the sensitivity parameters of the impact
sensor.
EEd
Movement stopped by the intervention of the safety
edge (EDGE input).
• EDGE input activated.
• Verify that the device connected to the EDGE
input is working properly and configured.
Eth
Thermal intervention to safeguard the board.
• Wait for the automation to cool down before
performing further handling.
• Please ensure that you do not exceed the use
threshold indicated in this user manual.
EME
Error in remote control memory. Memory not
installed or not recognized.
• Remove and insert the remote control memory
again.
• Perform the remote control memory reset proce-
dure (TRF parameter).
• Replace the remote control memory with a new
one.
FUL
Full remote control memory. It is no longer possible
to learn more remote controls.
• Clear some remote controls.
• Replace the remote control memory with a new
one.
Err
Error in memory query during learning functions,
position display or transmitter deletion.
• Incorrect selected memory location.
• Replace the remote control memory with a new
one.
EbS
Overcurrent error on motor output.
• Switch o the system and verify that the con-
nected motor is suitable for the type of control
unit in use and that there are no short circuits or
malfunctions on the engine in use.
• If the error persists contact technical support.
NOTE
Message reporting persists as long as the event persists or until the DOWN button is pressed or a handling