EasyManua.ls Logo

AllTrade 830211 - User Manual

Default Icon
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Model #830211
Modelo #830211
2
Air Compressor
Compresor de Aire
Gallon
Please retain these instructions for future reference.
If you encounter any problems or difficulties,
please contact our toll free Customer Service Department at:
1-800-423-3598
1-310-522-9008 (California only)
1-310-522-9066 Fax
Prière de conserver ces instructions pour pouvoir y référer à l'avenir.
En cas de problèmes ou de difficultés,
prière de contacter notre Service Après-Vente au numéro d’appel gratuit:
1-800-423-3598
1-310-522-9008 (En Californie seulement)
1-310-522-9066 Fax
Por favor, guarde estas instrucciones para que le sirvan de referencia en el futuro.
Si usted se encuentra con algún problema o dificultad, por favor, comuníquese con nuestro
Departamento de Servicios para el Consumidor, llamando de forme gratuita al:
1-800-423-3598
1-310-522-9008 (solamente dentro del estado de California)
1-310-522-9066 Fax
Question and Answer IconNeed help?

Do you have a question about the AllTrade 830211 and is the answer not in the manual?

Summary

Safety and Operating Guidelines

General Warnings

Important safety precautions to prevent injury and equipment damage during operation and maintenance.

Grounding Instructions

Proper grounding procedures to prevent electric shock and ensure safe electrical connections.

Extension Cord Usage

Guidelines for selecting and safely using extension cords with the air compressor.

Assembly Instructions

Steps for unpacking, checking parts, and initial assembly of the air compressor.

Product Features and Operation

Automatic On;Off Pressure Switch

Explanation of the automatic pressure switch that controls the pump motor based on tank pressure.

Regulator

Function of the regulator for selecting and controlling air pressure output to tools.

Tank Pressure Gauge

Description of the gauge that indicates the air pressure inside the compressor tank.

Safety Valve

Details on the safety valve that activates if tank pressure exceeds the maximum rated pressure.

Tank Drain Fitting

Instructions for draining water and moisture from the air tank to prevent corrosion.

Thermal Shutdown Switch

Information on the automatic thermal overload protector for the electric motor.

Start Up Procedure

Step-by-step guide for starting the air compressor and setting pressure.

Storage

Instructions for proper storage of the compressor to maintain its condition.

Maintenance

Guidance on maintenance tasks, including lubrication and moisture draining.

Troubleshooting

Compressor Will Not Run

Diagnosing and resolving issues when the compressor fails to start or operate.

Tank Pressure Drops

Troubleshooting why tank pressure decreases when the compressor shuts off.

Compressor Runs Continuously

Identifying causes and solutions for the compressor motor running without stopping.

Excessive Starting and Stopping

Addressing frequent cycling of the compressor motor, often due to moisture.

Summary

Safety and Operating Guidelines

General Warnings

Important safety precautions to prevent injury and equipment damage during operation and maintenance.

Grounding Instructions

Proper grounding procedures to prevent electric shock and ensure safe electrical connections.

Extension Cord Usage

Guidelines for selecting and safely using extension cords with the air compressor.

Assembly Instructions

Steps for unpacking, checking parts, and initial assembly of the air compressor.

Product Features and Operation

Automatic On;Off Pressure Switch

Explanation of the automatic pressure switch that controls the pump motor based on tank pressure.

Regulator

Function of the regulator for selecting and controlling air pressure output to tools.

Tank Pressure Gauge

Description of the gauge that indicates the air pressure inside the compressor tank.

Safety Valve

Details on the safety valve that activates if tank pressure exceeds the maximum rated pressure.

Tank Drain Fitting

Instructions for draining water and moisture from the air tank to prevent corrosion.

Thermal Shutdown Switch

Information on the automatic thermal overload protector for the electric motor.

Start Up Procedure

Step-by-step guide for starting the air compressor and setting pressure.

Storage

Instructions for proper storage of the compressor to maintain its condition.

Maintenance

Guidance on maintenance tasks, including lubrication and moisture draining.

Troubleshooting

Compressor Will Not Run

Diagnosing and resolving issues when the compressor fails to start or operate.

Tank Pressure Drops

Troubleshooting why tank pressure decreases when the compressor shuts off.

Compressor Runs Continuously

Identifying causes and solutions for the compressor motor running without stopping.

Excessive Starting and Stopping

Addressing frequent cycling of the compressor motor, often due to moisture.

AllTrade 830211 Specifications

General IconGeneral
Power SourceElectric
Maximum Pressure100 PSI
Max Pressure100 PSI
Voltage120 V
CFM at 40 PSI0.7 CFM

Related product manuals