GEM80-400 Product Overview
Issue 3 04/99 ALSPA GEM80-400 SERIES CONTROLLERS TECHNICAL MANUAL Page xxvii
5.3.2. Fast I/O with GEM80-400 Enhanced Controllers
Fast I/O Modules may be used within a GEM
80-400 Enhanced system by moving
the coding plug for slot 1 from the Central Highway position to the Fast I/O
position, fitting a 8300-4003 Fast I/O Driver Module in the controller subrack, and
connecting the controller subrack to Fast I/O Subracks using the 50-way ribbon
cable connector mounted on the rear of the GEM
80-400 Enhanced Controller
Backplane.
The Fast I/O Modules are accessed in the normal way via C- and D-tables.
Status linking is not provided.