M2x2/EN M/F User Manual
iSTAT M2x2
Page 33
11. HARDWARE FUNCTIONS
11.1 Installation Wizard
The Installation Wizard is designed to take the user through the minimum functions
necessary to install the M2x2. By pressing the OK key the following functions can be set:
Language: Connection Mode: VT Primary: VT Secondary: CT Primary: CT Secondary:
Device Address: Baud Rate: Parity: Stop Bit.
From the Installation Wizard is located on the Main Menu. Press OK to activate the Wizard.
Installation
Figure 12-1
Welcome to the
Installation wizard.
Press OK to continue
Installation Wizard display
<- Main Menu
Back to main menu
Figure 12-2 shows the Language setting structure. The selection is made by pressing either
the DOWN or UP keys until the desired language is selected and then press OK key to
make a selection.
Language
Figure 12-2
English
Francais
Deutch
Espanol
Russian
Dansk
Italian
US English
Language display
OK Select
Figure 12-3 shows the Connection Mode setting structure. The selection is made by pressing
either the DOWN or UP keys until the desired connection mode is selected and then
press OK key to confirm. The LEFT key can be pressed to return to the Language setting.
Connection
Figure 12-3
1b (1W)
3b (1W3)
4b (1W4)
3u (2W3)
4u (3W4)
Connection display
OK Select
Figure 12-4 shows the VT Primary setting structure. An underscore shows the position of
the curser. Move along by using the RIGHT or LEFT key, changes are made by pressing

Table of Contents