- 2 - 6062
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A.
II6062 - Rev. 032211 L01Q
MEMBER
6062 Typical Applications:
For this application Switch #1 and Switch #4
should be in the OFF position.
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
Fig. 2 - Guard Tour Supervisory Timer: Fig. 6 - Timed Shunt for a Door: Use to bypass alarm contacts.
TRG -- +
Closed
Circuit
Contact
Pull up
Resistor
Power
Supply
+
---
TRG -- +NOCNC
Bell
Output
Control Panel
12VDC or 24VDC
Fig. 1 - Timed Door Annunciator: Fig. 5 - Timed Door Strike:
For this application Switch #1 and Switch #4
should be in the OFF position.
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
Fig. 3 - Swinger Eliminator: Fig. 7 - Bell Cut Off Timer:
For this application Switch #1 should be in the OFF position
and Switch #4 should be in the ON position.
For this application Switch #1 should be in the ON position
and Switch #4 is not used in this application.
Fig. 4 - Delay Timer: Use for Door Ajar Alarm, Delayed
Activation of Digital Dialer, Defrost Cycle Timer, etc...
Fig. 8 - Closed Circuit Trigger Option:
For this application Switch #1 should be in the ON
position and Switch #4 is not used in this application.
For this application a resistor [for 12VDC - 2K (2,000 ohm)
or for 24VDC - 4.7K (4,700 Ohm)] must be installed as
shown (resistor not supplied).