CUT JI FOR REPEAT J1
1 2 3 4
ON
TRIG CONTROL 4
12V / 24V 3
SEC. / MIN. 2
RELAY CONTROL 1
TRG --- + NO C NC
1
ON OFF
15
CUT J3 FOR RESET
ON POWER-UP
J3
CUT J2 FOR DELAY PULSE J2
45
60
6062 Typical Applications
Fig. 1 - Timed Door Annunciator:
For this application Switch #1 and Switch #4 should be
in the OFF position.
Fig. 5 - Timed Door Strike:
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
Fig. 2 - Guard Tour Supervisory Timer:
For this application Switch #1 and Switch #4 should be
in the OFF position.
Fig. 6 - Timed Shunt for a Door: Use to bypass
alarm contacts.
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
CHIME
Pos (+) and Neg (-)
terminals constant 12
or 24VDC
+
--
Nor
mally open door contacts
CUT JI FOR REPEAT J1
1 2 3 4
ON
TRIG CONTROL 4
12V / 24V 3
SEC. / MIN. 2
RELAY CONTROL 1
TRG --- + NO C NC
1
ON OFF
15
CUT J3 FOR RESET
ON POWER-UP
J3
CUT J2 FOR DELAY PULSE J2
45
60
DIALER OR
TRANSMITTER
Pos (+) and Neg (-)
terminals constant 12
or 24VDC
+
--
Nor
mally open switch contacts
CUT JI FOR REPEAT J1
1 2 3 4
ON
TRIG CONTROL 4
12V / 24V 3
SEC. / MIN. 2
RELAY CONTROL 1
TRG --- + NO C NC
1
ON OFF
15
CUT J3 FOR RESET
ON POWER-UP
J3
CUT J2 FOR DELAY PULSE J2
45
60
Pos (+) and
Neg (-) ter
mi-
nals constant
12 or 24VDC
+
--
Nor
mally open door contacts
Door Strike
CUT JI FOR REPEAT J1
1 2 3 4
ON
TRIG CONTROL 4
12V / 24V 3
SEC. / MIN. 2
RELAY CONTROL 1
TRG --- + NO C NC
1
ON OFF
15
CUT J3 FOR RESET
ON POWER-UP
J3
CUT J2 FOR DELAY PULSE J2
45
60
Pos (+) and Neg (-)
terminals constant 12
or 24VDC
+
--
Normally open switch contacts
Door Contacts
Pr
otective Circuit
+
--
+
--
Fig. 3 - Swinger Eliminator:
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
Fig. 7 - Bell Cut Off Timer:
For this application Switch #1 should be in the ON position
and Switch #4 is not used in this application.
CUT JI FOR REPEAT J1
1 2 3 4
ON
TRIG CONTROL 4
12V / 24V 3
SEC. / MIN. 2
RELAY CONTROL 1
TRG --- + NO C NC
1
ON OFF
15
CUT J3 FOR RESET
ON POWER-UP
J3
CUT J2 FOR DELAY PULSE J2
45
60
Control Panel
12 or 24VDC
BELL
OUTPUT
BELL OR
SIREN
CUT JI FOR REPEAT J1
1 2 3 4
ON
TRIG CONTROL 4
12V / 24V 3
SEC. / MIN. 2
RELAY CONTROL 1
TRG --- + NO C NC
1
ON OFF
15
CUT J3 FOR RESET
ON POWER-UP
J3
CUT J2 FOR DELAY PULSE J2
45
60
Pos (+) and Neg (-)
terminals constant 12
or 24VDC
+
--
Protective
Circuit
Closed Circuit
Zone on Control Panel
+
--
Fig. 8 - Closed Circuit Trigger Option:
CUT JI FOR REPEAT J1
1 2 3 4
ON
TRIG CONTROL 4
12V / 24V 3
SEC. / MIN. 2
RELAY CONTROL 1
TRG --- + NO C NC
1
ON OFF
15
CUT J3 FOR RESET
ON POWER-UP
J3
CUT J2 FOR DELAY PULSE J2
45
60
Power
Supply
+
--
closed
cir
cuit contact
Fig. 4 - Delay Timer: Use for Door Ajar Alarm,
Delayed
Activation of Digital Dialer, Defrost Cycle
Timer, etc...
For this application Switch #1 should be in the ON
position and Switch #4 is not used in this application.
CUT JI FOR REPEAT J1
1 2 3 4
ON
TRIG CONTROL 4
12V / 24V 3
SEC. / MIN. 2
RELAY CONTROL 1
TRG --- + NO C NC
1
ON OFF
15
CUT J3 FOR RESET
ON POWER-UP
J3
CUT J2 FOR DELAY PULSE J2
45
60
Pos (+) and Neg (-)
terminals constant
12 or 24VDC
+
--
Use appropriate contacts to reporting devices
Normally open triggering device
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.
II6062 - Rev. 120104
L01D
MEMBER
Pull up resistor
For this application a resistor [for 12VDC - 2K
(2,000 ohm) or for 24VDC - 4.7K (4,700 ohm)] must be
installed as shown. (resistor not supplied)
Altronix is not responsible for any typographical errors.

Other manuals for Altronix 6062

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Altronix 6062 and is the answer not in the manual?

Altronix 6062 Specifications

General IconGeneral
Timer type-
Product colorBlue
Number of modules1
AC input voltage24 V

Related product manuals