Operating sequence fertiliser spreader ZA-M
AMATRON II-A DB 599 09.01
one job) (Fig. 11/1) After pressing key
=
Eingabe
Input
the
entered value is stored.
F
Enter the value for the desired spread
rate with the vehicle stopped.
F
During fertiliser spreading the spread
rate can be adjusted via the keys
-10 %
+10 %
in +/- 10 %-steps (please
refer to para. 6.5.4).
By pressing key
T2
(Start), you will get into
the display "Start job?" (please see para. 6.3.1).
By pressing key
T4
(Next), a comment can
then be filed in the data block "job" (see para.
6.1.3).
6.1.3 Menu "Comment"
Fig. 12
Here you can file a comment (Fig. 12/1), e.g. de-
tails about the weather etc. Entering via the 10-digit
key board (see para. 6.1.1). Name and comment
are not necessary for the operational procedure,
however they ease the later reading and assign-
ment of data.
Also in this case the data are only stored by
pressing the input key.
By pressing key
T2
(Start) the job can be
started also from here. Automatical change into
the operational data.
By pressing key
T4
(Next) now the imple-
ment serial number is displayed (please refer to
para. 6.1.4).
6.1.4 Menu "Implement serial number"‘
Fig. 13
With the initial operation of the machine (Fig. 13/2)
the implement serial number (Fig. 13/1) is auto-
matically issued and will later on be automatically
selected, i.e. no entry is necessary.
If different implements of the same type are con-
nected with AMATRON II-A (e.g. a second fertiliser
broadcaster with different implement data), the
individual machines must receive different imple-
ment serial numbers (e.g. enter the next free num-
ber for the second spreader).
After connection the second spreader can be acti-
vated by entering its serial number via the ten digit
key board.
By pressing key
T1
(Menu) and key
T4
(Next) return to the menu selection.
Start the job by pressing key
T2
(Start).
However, beforehand enter the necessary data
into the data block "machine" as otherwise error
messages would occur (see para. 6.6).
By pressing key
T3
(Delete) all data can be
deleted. Corrections are also possible while
entering via key
C
.
F
It is useful to select in the menu se-
lection now the data block "machine"
via the key
T3
in order to enter the
required data for the job (see para.
6.2).