Operating sequence field sprayer
51
AMATRON II-A DB 599 09.01
7.6 Alarm
In case of missing inputs, critical implement condi-
tion or grave input mistakes AMATRON II-A re-
leases a visual and audible alarm.
Required value
Fig. 97
The entered required rate (spray rate) cannot be
maintained, because, e.g. the speed is too high. As
soon as the speed has been adapted or e.g. the
required rate has been reduced, the alarm signals
will stop.
Tank filling
Fig. 98
The tank is empty or it only contains the amount for
which an alarm value had been set.
Fill the tank and enter the values into the computer
as described in para. 7.3.3.
Pressure range
Fig. 99
AMATRON II-A adjust the pre-set spray rate within
the prescribed pressure range of the nozzles.
Now the operator would have to change the travel-
ling speed in such a way that the pressure remains
within the allowed range (please refer to the in-
struction manual for the relevant field sprayer or to
the indicated values for the pressure range of the
different nozzle types).
F
Additional fault messages and their
remedy are described in para. 9..