3. ADJUSTMENTS AND CONNECTION
Tamper = Tamper terminal TAMPER =Morsetti tamper antiapertura
N.C. = Alarm terminals N.C.=Morsetti contatto allarme
EOL= END OF LINE Internal resistor terminal EOL= Morsetto reistenze interne di bilanciamento
(+ -) = power supply 13.8Vcc (+ -) = Tensione di alimentazione 13.8Vcc
DIP 1= walk test led OFF=Disabled - ON=enabled DIP1 =LED ON abilitato -dip OFF disabilitato
DIP 2 = pulse counter OFF=1 PULSE - ON=2PULSE DIP2 =Contaimpulsi OFF=1 impulso ON=2 impulsi
DIP 3 = range OFF= 7mt - ON = 15mt DIP3 = Portata OFF=7mt ON=15mt
REGOLAZIONI E COLLEGAMENTI
R1
R2
TAMPER
ALARM
JP1
2K2 2K2
5K6
5K6
4K7
4K7
1K
1K
EOL terminal
MOUSE 09
PANEL
R1 R2
open = alarm contact N.C.
closed = alarm contact balanced