4.2. Cleaning and storing the Secuquick softline
Clean parts in the dishwasher or clean them thoroughly by hand with a soft sponge and neutral deter-
gent. Rinse with hot water, dry well.
Depending on the food being prepared, the sealing ring can absorb odors. This is entirely nat-
ural. Store the sealing ring away from light and only loosely attached to the Secuquick softline.
Insert the sealing ring correctly again only before you next use it.
4.3. Assembling the Secuquick softline
Carry out the described inspection work during assembly. This inspection is important for safe and
correct operation.
Check operating pressure valve:
Must be easy to press in approx. 3-4 mm with finger.
Must spring back easily, with no sticking.
If the operating pressure valve does not function prop-
erly, the Secuquick softline must no longer be used.
Contact AMC customer service.
Check operating pressure valve:
The openings in the rubber section must be clean.
Metal pin must be present.
Check safety valve 2:
The O-ring must not be damaged.
The O-ring must lie in the groove (at the bottom).
The steel ball must not be stuck. Check by pressing
it with a finger whether it can move freely and springs
back.
Checking valves and seals
4. Care and maintenance
Care for and maintain the Secuquick softline as follows:
Take apart and clean after each use.
Before using it again, check that it is working properly: Valves and seals, condition of the cover
closure.
Replace the sealing ring and other seals if they are damaged, brittle, shrunken or cracked.
These parts should be replaced at least every two years or after 400 cooking cycles.
Use only original spare parts for the relevant 4300 model.
Wear parts (sealing ring and gaskets) are available as spare parts from AMC. These can be replaced by the
user or by an AMC service center.
All other interventions may be carried out only by an AMC service center.
Designation in user manual AMC item no.
Sealing ring 20 cm / 24 cm 10011155 / 10011156
Sealing washer for the operating pressure valve 10011151
Steam-venting valve 10011187
O-ring for safety valve 2 10011134
Sealing cap for safety valve 3 10011149
O-ring under the Visiotherm S 10011185
4.1. Disassembling the Secuquick softline
Unscrew bell nut (6). Detach the bottom cover (7) from the top cover (8).
Remove the sealing ring (9) (tip: use a small spoon handle to help).
Table: Original sealing rings and seals: