MEGAPOWER 48 / ADTTE 8200-0170-05, REV. A
OPERATION AND PROGRAMMING REFERENCE GUIDE 33 of 43
Configuring Switching
Settings
Use the Switching menu to program system tours,
salvos, and event timers.
SWITCHING
1 SYSTEM TOURS
2 SYSTEM SAL VOS
3 EVENT TI MERS
Programming System Tours
A system tour is a programmable sequence of
camera views that can be called for display on a
single monitor. Use System Tours to configure the
cameras, dwell times, functions, auxiliary, and
connect next settings for the 64 system tours.
SYST EM TOURS
TOUR - O1
ENTCAM DWLFUNCTAUXCN
01 0001 05 - - - - 0- N
02 0002 05 - - - - 0- N
03 0003 05 - - - - 0- N
04 0004 05 - - - - 0- N
05 0005 05 - - - - 0- N
06 0006 05 - - - - 0- N
07 0007 05 - - - - 0- N
08 0008 05 - - - - 0- N
The following settings are available:
Setting Description/Options
Ent
Entry (1-64): Relates to the order in
which items are displayed in the tour.
Cam
Camera: Generally relates to a camera
number, but may also represent a tour
or salvo number. The CN field is used
to identify if a camera, tour or salvo is
called.
Setting Description/Options
Dwl
Dwell time (1-61): The length of time
that a camera view is displayed on the
monitor(s) before switching to the next
tour entry. A dwell time can range from
1 to 60 seconds. An entry of 61 will hold
the current camera view displayed.
Funct
Function (PR or PT): Represents a
preset (PR) or pattern (PT) that is
called when a camera is selected.
Aux
Auxiliary: Activates the relay
associated with the selected camera for
auxiliary control. If no auxiliary action is
required for the tour entry, enter a zero
in this field. Relays 1-4 can be set to
On”. Relays 1-3 can be set to “Off”.
Cn
Connect Next: Four connect next
options are available.
N (no): The connect next function is not
enabled. The next tour entry displays
after the specified dwell time elapses. A
typical system tour that shows a
sequence of different camera views
uses this setting.
Y (yes): Connect next calls the next
tour entry to the next contiguous
monitor to emulate a salvo. A dwell time
is selected for the first entry.
Subsequent entries for the emulated
salvo must have a zero (blank) dwell
time.
S (salvo): A pre-programmed system
salvo is called for the specified dwell
time. The pre-programmed salvo
number is specified in the CAM field.
T (tour): A different pre-programmed
system tour is called. This selection
links two tours together to form a larger
camera sequence. A connect next
selection of tour can be made only for
the last entry in a system tour.
Note: A tour cannot call itself. In
addition, when a tour calls another tour,
the sequence does not automatically
return to the original tour unless
specified by a CN entry of the tour
being called.
Note: Programming examples for configuring
different tour entries are found in the MP48
Programming and Operation Manual. Refer to
these examples for specific details.