Details the four keys on the remote programmer: Enter, Cancel, Scroll Up, and Scroll Down.
Explains the steps to set the detection distance by interacting with the sensor using the programmer.
Disables the sensor for one minute to facilitate cleaning of the fixture or fitting.
Used in healthcare facilities for high-temperature or anti-bacterial purging of water lines.
Allows determination of faucet or flush valve settings, compatible with products manufactured from 2008.
Guides users through menu options to configure various device parameters.
Enables users to choose the display language for the programmer interface.
Allows adjustment of the display's backlight for optimal viewing in different lighting conditions.
Sets how long water runs after hands are removed from the detection zone. Recommended 1.5 sec.
Prevents continuous water flow if sensor is blocked. Recommended 55 sec.
Automatically flushes faucet after non-use to prevent stagnant water. Adjustable duration.
Sets the maximum detection range for Hand-Wash faucets. Recommended 16 cm.
Sets the run time for water flow when activated by the user in Metering mode.
Enables automatic flush after non-use to prevent stagnant water. Default setting is OFF.
Sets the maximum detection range for Metering faucets. Recommended 16 cm.
Sets run time; user starts/stops flow. Suited for gooseneck fittings with short detection.
Sets a short detection range for on/off functionality. Recommended 5 cm.
Time user must be in zone to arm flush valve. Eliminates false flushing. Recommended 5 sec.
Time after user leaves zone before valve flushes. Recommended 2 sec.
Configures large water delivery after pre-programmed flushes or time to prevent drain clogging.
Automatically switches to flush every 2 minutes during heavy usage periods.
Sets the maximum detection distance for urinal sensors. Recommended 40 cm.
Time user must be in zone to arm flush valve. Eliminates false flushing. Recommended 5 sec.
Time after user leaves zone before valve flushes. Recommended 2 sec.
Sets the maximum detection distance for toilet flush valves. Recommended 60 cm.
Sets flush time for users in detection zone for less than 1 minute.
Time user must be in zone to arm flush valve. Recommended 5 sec.
Time after user leaves zone before valve flushes. Recommended 2 sec.
Sets the maximum detection distance for toilet flush valves. Recommended 60 cm.
The document describes the "Selectronic Remote Control Operating Manual" for American Standard products, specifically focusing on the programming and operation of various sensor-activated fixtures like hand-wash faucets, metering faucets, on/off faucets, urinal flush valves, and dual-flush toilet valves. The manual outlines how to set detection distances, configure different operating modes, and adjust various parameters using a remote programmer.
The Selectronic Remote Control Programmer is a handheld device designed to configure and manage American Standard sensor-activated plumbing fixtures. It allows for precise adjustment of operational parameters, ensuring optimal performance and water efficiency for a range of applications, from public restrooms to healthcare facilities.
Function Description: The primary function of the remote programmer is to enable users to customize the settings of Selectronic sensors without direct physical interaction with the fixture's internal components. This includes:
Important Technical Specifications (as derived from the manual):
Usage Features: The programmer is operated using four keys:
The programming process generally involves:
For setting the detection distance, a specific procedure is outlined:
The programmer retains programmed settings for approximately 3.5 minutes after use, allowing for quick configuration of multiple sensors (Backup Function).
Maintenance Features:
Specific Mode Details:
The manual also includes a "Flush Valve Settings" chart, providing recommended settings (GPF, Detect Interval, Rinse Start, Rinse (Flush-Duration), Auto Rinse (Sanitary Flush), Auto Rinse (Run Time)) for various urinal, toilet, and dual-flush models (e.g., Innsbrook, 1.0 GPF, 0.5 GPF, 1.6/1.1 GPF). It advises using the 2016 sensor setting for products manufactured between 2008 and 2015 if unsure, and to try the 2008 setting if transmission errors occur.