AMETEK CTS AMP 200N series
Manual for Operation V 4.0.3 35 / 60
Figure 15 Setup for RI 140 If MN HField box is used the bridge must be shorted
RI 140 Test Parameter requirements
Figure 16 Graph for RI 140
Range
Frequency [kHz]
Level [dBpT rms]
Frequency step [kHz]
Range 1
0.05 1
165 20 log ( f/0.05)
0.05
Range 2
1 10
139
0.5
Range 3
10 - 100
139 20 log (f/10)
5