12.4.4 Immunity from Continuous Power Line Disturbances: CI 210
The device shall be immune from continuous disturbances that occur on the vehicle’s low voltage (i.e. 13.5 VDC)
electrical distribution system.
Default test setup
Figure 19 Setup for CI 210 closed loop with scope
RI 210 Test Parameter requirements
Figure 20 Graph for CI 210
Range
Frequency [kHz]
Us [Vp-p]
Frequency step [kHz]
Fig. 8.11: Interference Signal
Range 1
0.05 1
0.2
0.05
Range 2
1 10
0.2 x f
0.5
Range 3
10 - 100
2.0
5