9.8 Function of the analogue input
AI+/AI-
The input circuit of the analogue input is designed
as di󰀨erential amplier with an input resistance of 100
kOhm. In the set value voltage range of 0 ... +10 V, the
motor speed is changed by 0 ... 4092 rpm.
Set value voltages over +10 V are allowed, but do not
e󰀨ect any increase of motor speed.
Note:
A not connected analogue input equals 0 rpm.
9.8 Funktion des Analogeinganges AI+/AI-
Die Eingangsschaltung des Analogeingangs ist als
Di󰀨erenzverstärker mit einem Eingangswiderstand
von 100 kOhm ausgelegt. Im Sollwertspannungsbe-
reich von 0 ... +10 V wird die Drehzahl von 0 ... 4092
rpm verändert.
Sollwertspannungen über +10 V sind zulässig, bewir-
ken aber keine weitere Erhöhung der Drehzahl.
Hinweis:
Ein nicht angeschlossener Analogeingang entspricht
einer Drehzahl von 0.