Installation
2-4 TM-F2OP-C1XN-01
5. If storing, stack no more than eight cartons high. Check the storage
temperature range and storage altitude specification in
“Environmental Specifications” on page A–9.
Location, Mounting, and Ventilation
Use the power supply in rack-mounted or benchtop applications.
Rack Mounting
The power supply is designed to fit in a standard 19 in. (483 mm)
equipment rack. To install:
1. Use the rack mount brackets at either side of the front panel to install
the power supply in a rack.
2. Provide adequate support for the rear of the unit without obstructing
the ventilation inlets on the sides of the unit. Use a support bar at the
rear of the unit. Follow the manufacturer's instructions to install the
support bar.
To install the power supply with rack mount slides, use a commercially–
available slide kit. Follow the manufacturers instructions to install the
slides. Add a 1/8 in. (3.0 mm) spacer between the chassis and the slides.
POWER SUPPLY
Model Number:
Serial Number:
FRAGILE — ELECTRONIC EQUIPMENT
Figure 2-1
Shipping or Storage Carton Label
WARNING: Shock hazard
Ensure that any mounting screws do not penetrate more than 1/8 in. (3.0 mm) into
the sides of the unit.