Specifications
A-10 TM-F2OP-C1XN-01
Mechanical Specifications
Front Panel V and I Control 10-turn voltage and current
potentiometers
Front Panel Voltage Control
Resolution
0.02% of maximum voltage
Front Panel Voltage and Current
Meters
3.5-digit green numeric LED displays. For
accuracy specifications, see Table A-1 on
page A–2 and Table A-2 on page A–4.
AC Input Connector Type 3-terminal 34 A, 250 V, right angl
e, PC
mount, wire clamp connector with
rem
ovable strain relief cover
Input Fuses
a
1 A, 250 V, 5 x 20 mm slow fuse (T),
location: F34;
1.5 A, 250 V, 5 x 20 mm time delay (T),
location: F33; 20 A, 250 Vac, 5 x 20 mm
fast high interrupt (F), location: F36;
30 A, 300 Vac, 10.3 x 41.3 mm medium
time lag (T), locations: F2, F3.
Output Connector 7.5 V to 100 V models: nickel-plated
copper bus bars with removable bus bar
shield; bus bar holes: 0.343 in. (8.7 mm)
diameter (D) (1), 0.197 in. (5.0 mm) D
(2);
150 V to 600 V models: 4-terminal, right
angle, PC mount, wire clamp connector
with removable strain relief cover.
Sense Connector 5-terminal wire clamp connector (2 piece)
Analog Programming Connector 15-terminal wire clamp connector (2
piece)
Chassis Ground One chassis ground screw located on rear
panel for bonding connections or for wire
shield grounding. Maximum penetration
into unit is 0.375 in. (9 mm).
Cooling Fan cooled. Air exhausts to rear. Over
temperature shutdown: automatic restart
or latch off (switch-selectable).

Table of Contents