4
overfilled with oil, as this can affect normal operations. In
addition make sure to change the oil on a regular basis.
1 .14 Refrain from using the air compressor when
welding. Also, it is recommended that you disconnect all
sources from the generator as well when welding.
2. Specifications
Welding current
range (A)
DC 50 200
Duty cycle ( % )
50
power static
characteristic curve
dropping characteristic
Generating
Rated voltage (V)
AC 240/120
Rated output (KW)
5
Max output (kW)
5.5
Air
compressing
Starting
Recoil start + pressure trigger
Air tank (Gal)
2X 2.5
Alternator output
1 . 35
Pressure( PSI )
115
Air output (CFM)
4.4 @ 90pSl
Air input( CFM )
8
engine
Speed control
Manual operation
Cooling system
Air cool
Air valve
OHV
Ignition system
CID
Fuel Tank (Gal)
7.9
Oil alert system
Yes
Fuel consumption
(g/hp.hr)
374
Start Mode
Recoik electric Remote Start
LengthxWidthxHeight
Machine size: