155
VG Series Modero Touch Panels
2. Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected Setup page and
display an on-screen keypad.
3. Enter 1988 into the Keypad’s password field and press Done when finished.
4. Press the System Settings button (located on the Protected Setup page) to open the System Settings page and obtain
the IP information from the IP Address field (FIG. 131).
Step 2: Configuring the MAX-CSE for communication
1.
Complete the procedures outlined within the Configuring the MAX Communication Parameters section of the
MAX-CSE Instruction Manual to establish an active connection to the source MAX-CSE.
2. Confirm the MAX-CSE is properly configured to use the newly established Static IP Address by launching your
browser and entering the MAX’s new Static IP Address into the browser’s Address field.
3. Press the Enter key on your keyboard to initiate the communication process and launch the initial on-screen Enter
Network Password security dialog.
4. Enter the words administrator and password (if using the default login profile) into the corresponding User Name/
Password fields. This is the factory default security login information.
5. Click OK to enter the information and proceed to the Administration page which provides both a descriptive
overview of the program stream and lists the currently used firmware.
6. Determine the data throughput available on the network being used by the source encoder. This information
determines which Encoder Profile and Transport Protocol will be used to encode the outgoing media stream.
7. Access Stream Profiles page (FIG. 132) by clicking the Stream Profiles link from within the Navigation frame.
This page allows a user to both configure the properties of the outgoing media stream and setup the properties
associated with communicating the stream to an external IP-enabled device capable of receiving and processing the
data.
FIG. 131 System Settings page