Firmware Pages and Descriptions
120
Modero VG Series Touch Panels - Instruction Manual
Refer to the Step 2: Choosing a Master Connection Mode Setting section on page 85 for more detailed information on using the
System Settings page.
Sensor Settings Page
The Sensor Settings page (FIG. 118) allows you to adjust the Light and Motion Sensor parameters on a Modero touch panel.
NOTE: A light level value between the Minimum and Maximum DIM Mode values delivers an average light level. The DIM mode Min Level
can never exceed the DIM Mode Max Level.
The elements of the Sensor Settings page are described in the table below:
System Settings Page Elements (Cont.)
Master Connection (Cont.):
Type Sets the NetLinx Master to communicate with the panel via either USB or Ethernet. This is based on the
cable connection from the rear.
ICSNet is not a supported option on this panel.
• Ethernet is a CAT-5 cable (10/100Base T terminated in an RJ-45 connector) used to network
computers together and is used in most LAN (local area networks). This description is also used to
refer to both wired and wireless communication.
• USB option cannot be used on Modero panels which are not equipped with a rear USB port.
Mode Cycles between the different connection modes (URL, Listen, and Auto) (ETHERNET Only - disabled when
USB is selected)
• URL - In this mode, enter the IP/URL, Master Port Number, and username/password (if used) on the
Master.
- The System Number field is read-only because the panel obtains this information from the
communicating Master.
• Listen - In this mode, add the Modero panel address into the URL List in NetLinx Studio and set the
connection mode to Listen. This mode allows the Modero touch panel to "listen" for the Master’s
communication signals.
- The System Number and Master IP/URL fields are red-only.
• Auto - In this mode, enter the System Number and a username/password (if applicable). This mode is
used when both the panel and the NetLinx Master are on the same Subnet and the Master has its UDP
feature enabled.
- Master IP/URL field is read-only.
System Number Allows you to enter a system number. Default value is 0 (zero).
(ETHERNET Only - disabled when USB is selected)
Master IP/URL Sets the Master IP or URL of the NetLinx Master.
(ETHERNET Only - disabled when USB is selected)
Master Port Number Allows you to enter the port number used with the NetLinx Master.
• Default value is 1319. (ETHERNET Only - disabled when USB is selected)
Username/Password If the target Master has been previously secured, enter the alpha-numeric string (into each field)
assigned to a pre-configured user profile on the Master. This profile should have the pre-defined level of
access/configuration rights.
FIG. 118 Sensor Settings page
Sensor Settings Page Elements
Back: Saves the changes and returns you to the previously active touch panel page.
Connection Status icon: This visual display of the connection status allows the user to have a current visual update of the panel’s
connection status regardless of what page is currently active.
• A Lock only appears on the icon if the panel has established a connection with a currently secured target
Master (requiring a username and password).