122
Modero VG Series Touch Panels - Instruction Manual
5. Set the Maximum brightness of the Dimmer (Dim Mode Max Level) below the detected drop. This will make sure that the panel
does not react to variations in the lighting conditions of a normal working environment.
NOTE: The maximum (upper level) of the dimmer should be at least 15% lower than the maximum detected level.
6. Set the minimum lighting conditions in the room (not complete darkness but the minimal lighting setup, unless complete
darkness is an “operational option” for the room).
7. Set the Minimum Dimmer Brightness (Dim Mode Min Level) to a comfortable level by sitting in front of the panel. You should be
able to comfortably see someone sitting behind the panel without being “blinded” by the panel.
8. Move around the panel and block the direct or indirect light from the room fixtures with your body. Take note of the drop in the
lighting level being detected by the panel in response to your movements.
9. Set the Minimum brightness of the Dimmer (Dim Mode Max Level) below the detected drop. This will make sure that the panel
does not react to variations in the lighting conditions of a normal working environment.
NOTE: The minimum (lower level) of the dimmer should be at least 10% lower than the minimum detected level (ex: lower
dimmer level at 30% if the detected lighting of the room is at 40%).
Calibration Page
This page (FIG. 119) allows you to calibrate the input touch device (touch panel) using the pre-selected touch driver.
Press and hold the grey Front Setup Access button (below the Modero LCD) for 6 seconds to access the Calibration page.
Press the crosshairs to calibrate the panel and return to the last active firmware page.
NOTE: If the calibration was improperly set and you cannot return to the Calibration page (through the panel’s f irmware); you can
access this f irmware page via G4 WebControl, where you can navigate to the Protected Setup page and press the Calibrate button
through your VNC window. This action causes the panel to go to the Calibration page seen above, where you can physically
recalibrate the actual touch panel again using the above procedures.
G4 Web Control Settings
The G4 Web Control Settings page (FIG. 120) centers around enabling and disabling both the display and control of your panel (via
the web). An external PC running a VNC client (installed during the initial communication to the G4 panel) makes this possible.
Each panel supports the open standard Virtual Network Computing (VNC) interface. These panels contain a VNC server that allows
them to accept a connection from any other device running a VNC client. Once a connection is established to that target device, the
client can control the touch panel remotely. The elements of the G4 Web Control page are described in the table below:
FIG. 119
Calibration page (actually 3 separate screens)
FIG. 120 G4 Web Control page
The request to touch the crosshairs
is the first on-screen message
Calibration successful is the second
on-screen message that appears