Firmware Pages and Descriptions
128
Modero VG Series Touch Panels - Instruction Manual
Checking the Panel Statistics
1. Press the Too ls button in the Protected Setup Navigation Buttons section. This opens the Tools menu.
2. Within the Tools menu, press the Panel Statistics button. All connection statistics are contained on this page, e.g., Received,
Processed, and Dropped ICSP Messages.
Refreshing the Panel Statistics
1. Press the Too ls button in the Protected Setup Navigation Buttons section. This opens the Tools menu.
2. Within the Tools menu, press the Panel Statistics button.
3. Push the Refresh button.
Clearing the Panel Statistics
1. Press the Too ls button in the Protected Setup Navigation Buttons section. This opens the Tools menu.
2. Within the Tools menu, press the Panel Statistics button.
3. Push the Clear button.
4. Confirm your selection.
Connection Utility
The options on the Connection Utility popup window (FIG. 128) allow you to utilize your panel as a site survey tool. While in this
page, move around your wireless network coverage area and see if there are any weak points within the spaces between your WAPs.
Features on this page include:
Connection Status icon: The icon in the upper-right corner of each Setup page shows online/offline state of the panel to the master.
Bright red - disconnected
Bright green - connected. Blinks when a blink message is received to dark green every 5 seconds for half a
second then go back to bright green.
Bright yellow - panel missed a blink message from the master. It will remain yellow for 3 missed blink
messages and then turn red. It will return to green when a blink message is received.
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx Master.
ICSP Messages Messages sent between the master and the touch panel; it is the protocol they use to communicate to each
other.
Total Received - The total ICSP messages received by the panel.
Processed - The total ICSP messages processed by the panel.
Dropped - The total ICSP messages dropped by the panel.
Last 15 Minutes Received - The total ICSP messages received by the panel in the last 15 minutes.
Processed - The total ICSP messages processed by the panel in the last 15 minutes.
Dropped - The total ICSP messages dropped by the panel in the last 15 minutes.
Blink Messages The master sends this message once every 5 seconds to all connected devices.
Total Received - The total Blink messages received by the panel.
Missed - The total Blink messages missed by the panel.
Last 15 Minutes Received - The total Blink messages received by the panel in the last 15 minutes.
Missed - The total Blink messages missed by the panel in the last 15 minutes.
Ethernet Statistics The Ethernet connection statistics for the panel.
Wireless Statistics The Wireless connection statistics for the panel.
Clear Clears all panel connection statistics.
Refresh Refreshes all panel connection statistics.
FIG. 128 Connection Utility popup window