Installation Procedures: 17" Panels
60
Modero VG Series Touch Panels - Instruction Manual
NOTE: Verify the Strain Relief Grommet is securely closed over the cables and the clip is facing the correct direction (upwards).
The process of securing the strain relief grommet may require the use of pliers. Also verify the length and location of the inserted
cables. Once the strain relief grommet is closed, it is difficult to re-open.
5. Firmly push the Strain Relief Grommet into the opening (toward the inside) until the rim is securely flush against the back of
the rear plastic cover (FIG. 52).
6. Securely grasp both sides of the NXD panel (with LCD, MB-TP17 back box, and attached cables), rotate the entire unit over,
and lie it on a flat level surface.
7. Note the available mounting contact surface area on the rear plastic cover (FIG. 52). This area represents the space available
for use with a VESA connector plate.
8. Insert and secure the ten #6-32 securing screws into their pre-drilled holes along the edges of the NXD unit (FIG. 51). This
step secures the NXD unit to the rim of the rear plastic cover.
9. Align a VESA mount connector (purchased separately) to the four #8-32 screw holes on the back of the rear plastic cover
(FIG. 52).
10. Insert the four provided #8-32 screws through the VESA mount’s four holes and then into the pre-drilled holes on the rear
plastic cover.
NOTE: When installing a VESA mount to the rear plastic cover, use only the AMX provided #8-32 screws.
11. Secure these four #8-32 screws to the rear plastic cover by using a grounded Phillips-head screwdriver. This step secures the
VESA mount to the rear of the panel.
Refer to your particular VESA mount manufacturer’s installation procedures for further surface mounting procedures.
FIG. 52
MB-TP17 Mounting contact surface area
FIG. 53 Installation of grommet into the rear plastic enclosure
.83[21MM]
1.84[47MM]
4.06[103MM]
3.83[97MM]
Rear plastic cover (rear view)
Rim of the strain relief grommet
should lie flush against enclosure
CLIP FACING UP
VESA mount connection location
(USE ONLY AMX PROVIDED #8-32 screws)