Technology | High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) |
---|---|
Type | Atomic Absorption Spectrometer |
Wavelength Range | 185 - 900 nm |
Detector | CCD array detector |
Flame AAS | Yes |
Flame and Furnace | Yes |
Light Source | Xenon short-arc lamp |
Monochromator | Echelle monochromator |
Atomization Techniques | Flame, Graphite Furnace, Hydride |
Graphite Furnace Temperature Program | Programmable up to 3000°C |
Sample Introduction | Manual, Autosampler |
Resolution | High resolution |
Describes the primary function and application of the contrAA 700 spectrometer.
Explains the symbols and formatting used throughout the manual for clarity and safety.
Details the technical specifications of the contrAA 700, covering optical system, lamp, and power.
Lists compliance with relevant safety, EMC, and EC directives and standards.
Specifies the environmental conditions required for optimal installation and operation of the contrAA 700.
Explains the electrical power requirements and connection details for the contrAA 700.
Covers the necessary gas supplies, purity requirements, and pressure for instrument operation.
Illustrates the physical arrangement of the contrAA 700 and its components.
Explains the core atomic absorption spectrometry technique used by the contrAA 700.
Describes the xenon short-arc lamp as the continuum light source for the instrument.
Details the electrothermic atomizer (EA) and its components for graphite tube technique.
Lists accessories for the graphite tube technique, including autosamplers.
Describes the flame system, including gas control and burner types.
Lists accessories for the flame technique, such as autosamplers.
Identifies the main power switch, terminals for PC and accessories, and utility inlet ports.
Guides the user through the physical installation and connection of the contrAA 700.
Outlines the process for installing and launching the control software.
Details installation steps specific to the graphite tube technique.
Details the procedure for installing and adjusting the AS-GF autosampler.
Covers installation steps for flame technique setup and sample feeding.
Provides a quick overview of maintenance tasks, their reasons, and periodicity.
Covers maintenance for the basic system unit, including fuses and safety circuits.
Details maintenance procedures for the graphite tube furnace and its components.
Describes maintenance tasks for the burner-nebulizer system, including disassembly and cleaning.
Covers maintenance for the AS-GF autosampler, focusing on the dosing tube.