28
Do not place the refrigerated compartment near heat sources. (pict.25)
Remove pvc protective film from all over the appliance. (pict.26)
Place the appliance onto the required working site.
(pict.27)
Avoid locations with exposure to direct sunlight.
Do not place the appliance in hot, poorly-ventilated rooms.
Leave a min. 100-mm clearance around the appliance on the sides where air
inlet and outlet are located. (pict.28)
For models, depth 700, it is possible to bring the rear of the appliance closer to the
wall.
Level the appliance by means of adjustable feet. (pict.29)
In case of 72 kg and 144 kg blast chillers, set the
handle moving the washers before or after the P plate.
(pict.30)
Use suitable fork lift trucks to level heavier appliances
(20-kg models onwards).
WARNING: If the appliance is not properly levelled the performance and condensate drain may be
hampered.
Pict.25
Pict.26
Pict.27
Pict.28
Pict.29
Pict.30