5
P/N 1011458 Rev D 01/22
Specications
Electrical Ratings
Electrical Cord & Plugs
Water Requirements
Model &
Mfg. No.
Description Conguration
IS-1000
9010935
NEMA 6-50
250 VAC, 50 AMP
Model &
Mfg. No.
Volts Watts Amp Hertz
IS-1000
9010935
208
8400
Watts
41 50/60
Dimensions
(26.00)
(1.9)
Water Requirements
Water Quality (Treated Water)
Hardness (Calcium & Magnesium) 1 GPG Maximum
Total Alkalinity 600 PPM Maximum
Total Silica 150 PPM Maximum
Iron Content 0.1 PPM Maximum
pH 6.5-10.5
Total Dissolved Solids 2,500 PPM Maximum
Oxygen Content 0 PPM
Carbon Dioxide 0 PPM
Minimum Water Pressure 40 psig dynamic
Maximum Water Pressure 90 psig
Maximum Water Usage during normal
operation
3.5 gallons per hour
Maximum water usage during clean
cycle operation (Initial Fill 1.6 gallons;
ushing4.8gallons)
6.4 gallons
Water Inlet Connection
Water Pressure Requirements
Minimum Water Pressure 40 psig dynamic
Maximum Water Pressure 90 psig
IMPORTANT
Failure to follow these water quality conditions will void the
warranty and may cause the steamer to operate erratically or fail
prematurely and require a service call. To better understand if the
water to be used for the boiler meets these requirements, a water
qualitysamplekit(partnumber7002105)canbeorderedfrom
Antunes for testing.