9
IMPORTANT! This optional brine tank overfill connection step is not required. It’s for addi-
tional security against leaks and prevention of disrupted service purposes only.
Optional Brine Tank Overfill Connection:
Below the brine hose connection you will notice a 90-degree barbed connection facing downward. This
connection is optional since the brine well is equipped with an automatic float valve shutoff.
If you still want to utilize the overfill connection, lubricate the barbed connection with silicone grease or any
food-grade oil. You will need to purchase an additional ½” plumbing hose and place the hose onto the
connection for a secure seal. Typically, the other end of the hose will feed off into a floor drain, laundry style
sink, or dedicated drain connection.
Note:
Make sure the brine line is secure to the connection provided on the brine tank. If the brine
line is not secure and sealed, it may not be able to perform a proper system regeneration
when needed, and can potentially cause overfill in the brine tank and result in leaks.
7. Install overflow adapter to the salt tank and close with the well lid.