To shut off water to the system, please
position arrow handles as shown in the
bypass operation diagram to the right. If
your valve doesn’t look like the diagram,
contact your service technician for instructions
on how to shut off water.
Bypass Operation
Treated Out Untreated In
Bypass Operation
Untreated Out
Unt
reated In
2
Bypass Operation
Push NEXT until time of
day screen is displayed.
Press and hold until
SET TIME is displayed and
the hour flashes once.
Press or until the
correct hour is displayed.
Then press NEXT. The
minutes will flash. Press
or until the correct
mintue is displayed
Setting Time of Day
Press Next to return to the User Displays. Time
of day should only need to be set after power outages
lasting more than 8 hours, if the battery has been
depleted and a power outage occurs, or when daylight
savings time begins or ends. If a power outage lasting
more than 8 hours occurs, the time of day will flash
on and off which indicates the time of day should be
reset. If a power outage lasts less than 8 hours and
the time of day flashes on and off, the time of day should
be reset and the battery be replaced.