30 max.
45 max.
Size Plenum Box to fit outer housing
without door: 17
3
/4” x 28
1
/8”
See
Figure 2 for complete dimensions
FIGURE 8 FIGURE 9
FIGURE 6 FIGURE 7
FIGURE 4 FIGURE 5
Note: Air
Cleaner outer
housing can
support up to
400 lbs.
Left side
install shown
The Model 5000 can be installed in a
variety of ways. The figures below show
some of the possibilities.
The air cleaner may be installed on the
left or right side of the air handler. If
installed on the right, the ON/OFF switch
will be on top and the nameplate will be
on the bottom. Remove the nameplate
and rotate it 180° to read properly.
FIGURE 3 – Clearance for Inner Housing Removal
It is important to leave enough room to remove
and re-install the Inner Housing.
Allow Clearance for Removal of Inner Housing
for Filter Replacement.
Bottom Return in upflow
“Highboy” installation.
(Figure 4)
Inline in duct, horizontal
or vertical installation.
(Figure 5)
Side Return in upflow
“Highboy” installation.
(Figures 6 & 7)
Compact Side Return in upflow
“Highboy” installation (Figures 8 & 9).
Either of the methods shown in Figures
6 and 7 will result in a narrower
“footprint”, creating better clearance
in tight mounting applications.
90-666
90-1158 90-1159
90-1160 90-1161
90-1162
90-1163
Left side
install shown