Aprilaire E100 - Zoning the Dehumidifier

Aprilaire E100
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
FEET
MIN
AIR IS
PULLED FROM
OUTSIDE
A
B
C
6
FEET
MIN
AIR IS
PULLED FROM
OUTSIDE
A
B
ABOVE EXPECTED
SNOW LINE
NORTH, EAST OR
WEST SIDE OF HOME
A
B
36MAX
CENTER
LINE
OUTSIDE WALL
FIGURE 23: ONBOARD CONTROL VENTILATION INSTALLATION
FIGURE 24: EXTERNAL CONTROL VENTILATION INSTALLATION
FIGURE 25: ODT MOUNTED OUTSIDE
FIGURE 26: ODT MOUNTED IN INTAKE DUCT
90-1897
90-1898
B2202617-D
B2202617-E
A. NORMALLY CLOSED VENT DAMPER
B. BALANCING DAMPERS
C. HVAC/FURNACE
A. NORMALLY CLOSED VENT DAMPER
B. HVAC/FURNACE
A. OUTDOOR TEMPERATURE SENSOR
B. OUTDOOR TEMPERATURE SENSOR LEADS
VENTILATION
The dehumidier can activate a normally closed damper to
bring in outdoor air through a fresh air intake duct. This feature
cannot be used when a Model 76 has been installed in a
remote control application and should not be used in two-zone
installations.
1. Install the Fresh Air Inlet (FAI) duct and damper as shown in
FIGURE 23 and FIGURE 24.
2. Install the Outdoor Temperature Sensor (ODT) as shown in
FIGURE 25 and FIGURE 26 – only needed if ventilation will be
limited during high or low outdoor temperature conditions.