Commissioning
24 EN 06|2019
5.3.3 Filter operation
• Set the handle of the valve to “Filter”
Filter is ready for mechanical water treatment
• Switch the filter pump on.
5.3.4 Setting the filter time
• The operating time of the filter depends on the pool volume,
frequency of use, weather and chemicals.
• Circulate once to twice in 24 hr, e.g. pool volume: 10 m³,
should be circulated twice, meaning that 20 m³ has to be
pumped. The pump capacity is approx. 6 m³ per hour, so the
filter has to run for approx. 3 hr.
Take the output of the supplied pump into consideration.
• In order to achieve sufficient disinfection on hot days the filter
time has to be increased.
• Also run the pump on rainy days.