Electricity
When working on the electrical unit, there is an increased risk of electrocution due to the damp
surroundings.
Incorrectly installed protective conductors can also lead to electrocution e.g. as a result of oxidation or
cable breakage.
Make sure that the swimming pool and its surrounding protective zone are installed, commissioned and
operated in accordance with the relevant local regulations.
Before working on the electrical system, take the following precautions:
- Disconnect the system from the electrical power supply.
- Attach a warning sign: “Do not switch on! Work in progress on the system.”
- Check the absence of voltage.
Regularly check that the electrical system is in proper working order.
Hot surfaces
Risk of burns - the electric motor can reach temperatures of up to 70 °C.
- Do not touch the motor while it is running.
- Let the motor cool down before working on the pump.
3. General
Please take the necessary precautions when transporting the pump. During transportation, avoid
intermediate storage in a damp location or locations subject to signi cant temperature uctuations. Our
pump with integrated lter has been designed for pre- ltering and circulating swimming pool water.
Most plastic components that come into contact with the pumping medium are made of reinforced
polypropylene (PP). The water temperature must not exceed 40 (60) °C.
We cannot accept any liability if our installation and operating instructions are not observed.
4. Installation
The installation site of the pump must be dry and well ventilated.
When installed in a closed room, a drainage connected to the
sewers must be installed.
The size of the oor drain depends mainly on the size of the
swimming pool and the circulation ow rate but also on possible
leaks within the pool water circulation system.
The ambient temperature must not exceed 40 °C.
D42.02.206-P
Rotating parts
Risk of crushing or shearing from exposed rotating parts.
- Do not perform any work on the pump unless the power is shut down.
- Before starting work, make sure the pump cannot inadvertently be switched on again.
- Directly after nishing work, re t/reactivate all protective devices.