AQUA SALT EVO MAINTENANCE AND INSTRUCTION MANUAL
Salt chlorine generator ENGLISH
ADSP7000753 rev. 2.0 23/04/2019 53/96
53
1 Introduction
AQUA SALT EVO is a multi-function chlorine generator that
generates disinfectant active chlorine directly from the salt of the
pool. The system is designed for small and medium pools, up to 200
m
3
1.1
Warnings
Please read the label on the product and respect the following points:
At the receipt, make sure that generator's packaging and components are not broken or damaged. In
the event of a fault, please inform the qualified personnel before any operation.This manual must be
kept in a safe place for future reference.
Before installing the generator, make sure that the data on the label of the device correspond to those
of the electrical system .Do not use the device with wet hands or feet! Do not leave the device
exposed to the weather!The device must be used by trained personnel!In case of faults during the
operation of the generator, cut the power supply immediately and consult our service centres for
possible repairs.
For the correct operation of the generator, it is necessary to use original spare parts or accessories.
The manufacturer will not be held responsible for any fault or damaged provoked by tampering or
non-original spare parts and accessories
The electrical system must be complying with the standards of the Country it is installed in.
The temperature of the environment must not be above 45° C.
In order for the generation of chlorine takes place, the water temperature of the pool should be at
least 5° C.
Before the installation, read these instructions carefully and follow them during the process.
Failure to follow the instructions of this manual may cause personal harm and damage to the device
and/or the system.
1.3
Electrical
Features
• Power supply: European range from 180 to 260 VAC at 50/60 Hz
• Max. absorbed power: 300W
• Cell power supply: 24VDC at 10 A
• Max. chlorine production: 40 g/h
• Cell hydraulic connections: DN50 or DN63
• Max. operating temperature: 45°C
• Max. operating pressure: 3.75 bar
1.2
Reference
standards

Table of Contents