EasyManua.ls Logo

Aqua Salt Evo - Page 65

Aqua Salt Evo
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AQUA SALT EVO MAINTENANCE AND INSTRUCTION MANUAL
Salt chlorine generator ENGLISH
ADSP7000753 rev. 2.0 23/04/2019 65/96
65
The first section shows two columns: the left one shows the state of the device, the right one shows
the amount of chlorine generated (in mV or ppm) or the set chlorine percentage. You can modify the
% with the keys only if the state is Work, Start-Up and if the shutter is open. Ppm or mV values
are read-only. Possible state values are: Work, Work + Winter, Work+Shutter, Boost as specified
below:
• Work: the device is generating chlorine following the chosen operating mode.
• Work + Winter: the device is generating chlorine at a reduced operating mode according
to the percentage set.
• Work + Shutter: the device is generating chlorine, and the shutter is closed
• Boost: the generator is producing chlorine at 100% of its capacity (superchlorination)
Indicates the pool water pH value between 0 and 14. This item is displayed only if the type of unit
includes the presence of the pH probe.
The field indicates the Rx value measured in the pool water, expressed in mV. This item is displayed
only if the type of unit includes the presence of Rx probe.
Indicates the value of the chlorine in the pool water measured, expressed in ppm. This item is
displayed only if the type of unit includes the presence of chlorine Jumo probe.
A countdown timer that indicates the time left for the current work phase is visualized.
The left column shows the current phase of the device, and the right one shows the clock or the
remaining time. The clock shows the current time and it is shown during the following phases:
• Pause.
• Wait timer.
• Wait flow/pressure.
The value of the remaining time decreases with the time, and it regards the following phases:
• Flow/pressure stabilization.
• Work on.
• Work off.
• Clean.
The polarisation time
indicates the
frequency at which
the electrodes switch
their polarity.
The left column shows the
value of the voltage; The right
column shows value of the
current.
Indicates the amount of
chlorine generated in one hour.
This amount is an estimate.
This section indicates the
operating mode chosen,
among ”External timer”,
“Proportional”.
Indicates current pool
water temperature.
Indicates the current amount of
salt in the water. This value is
an estimate.
Indicates the average value of
salinity in the pool. This value
can be reset and recalculated
by pressing Enter.
This section indicates if water
flow/pressure within the
electrolytic cell or not.
You will visualize a timer that shows the hour, minutes and seconds left before the next check of the
electrolytic cell.
You will visualize a timer that shows the hour, minutes and seconds left before the next replacement
of the electrolytic cell.
clock phase
time left phase
Chlor
Rx
pH
time left
generator
operation
Flow & Pressure
estimated
chlorine
generation (g/h)
Cell check
Cell
replacement
average salinity
estimated
Instant salinity
estimeted
VOut IOut
polarisation time
Chlorine state
Temperature

Table of Contents