AQUA SALT EVO MAINTENANCE AND INSTRUCTION MANUAL
Salt chlorine generator ENGLISH
ADSP7000753 rev. 2.0 23/04/2019 72/96
72
5 Alarms
The alarm signal with the highest priority will be visible alternately
to the main section of the User menu, while the corresponding Led
(Alarm or Maintenance Led) will be enabled for all menus
5.1
High/low
temperature and
ice alarm
1) The High temperature alarm, which cannot be disabled from the alarms menu, goes off if
temperature read is higher than 60 °C.
✓ The device indicates:
• Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
• Red alarm LED steady on;
• “High temperature Alarm” flashing on the display;
During the alarm, the generator stops working.
The alarm is automatically reset when the probe reads a temperature value below 60 °C.
2) The Low temperature alarm, which cannot be disabled from the Alarm menu, goes off if
temperature goes below 5 °C.
✓ The device indicates:
• Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
• Red alarm LED steady on;
• “Low temperature Alarm” flashing on the display;
3) In case the temperature read by the probe goes below 2,5 °C and the ice alarm was enabled
from the Alarms menu, it will activate as well, together with the Low temperature Alarm.
✓ The device indicates:
• Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
• Red alarm LED steady on;
• “Ice Alarm” flashing on the display;
The ice alarm is reset when the alarm is disabled from the Alarms Menu. It is automatically reset
when the probe reads a temperature above 2,5°C. The Low temperature alarm is reset when the
values read are above 5 °C.
5.2
Flow &
Pressure alarm
The flow/pressure alarm, which cannot be disabled, goes off whenever the generator is operating,
but water flow/pressure is absent.
✓ The device indicates:
• Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
• Red alarm LED steady on;
• “Flow/Pres. alarm” flashing on the display;
When this alarm goes off, the generator stops working.
The alarm will be automatically reset as soon as water flow/pressure resumes in the electrolytic cell.
The flow sensor/pressure input has a recognition filter that lasts about 10 seconds to prevent false
contacts and undesired false alarms.
5.3
Cell
maintenance
alarm
The maintenance alarm activates when the generator worked for a longer time than the value set under
“Cell Maintenance” in the Alarms Menu.
The maintenance time can be set within a range of 100-1000 hours, at intervals of 100 hours.
The device indicates:
• Audible signal with the buzzer, if enabled (see Audible Alarm in the Alarms Menu);
• Red maintenance LED steady on;
• Cell check Alarm flashing on the display;
In spite of the alarm, the generator keeps working normally.To deactivate the alarm, after the
maintenance of the electrolytic cell has been carried out, go to section reset cell maintenance alarm.
Access the corresponding submenu by pressing Enter and reset the time of the cell maintenance
alarm.