Keep Hydroxy away from flames and sparks; it is non-combustible when mixed with air.
Mix lye and distilled water in a glass container in a ventilated area until dissolved.
Use only lye as catalyst; avoid citric acid. Solution may heat and emit fumes.
Pour cooled lye solution into the fill pipe, adding distilled water to reach the correct level.
Steps to take if the machine is overfilled, including draining excess solution.
Install the Tower Cap to prevent lye contamination and monitor foaming.
Install and fill the humidifier as a second defense against lye contamination.
Fill the bubbler to ensure pure breathing gas and act as the final lye trap.
Connect accessory tubes, check fluid levels, and plug in the AquaCure.
Set the timer switch for desired operation duration or continuous mode.