2 DIL—Setting flush interval
For 2 DIL switch controls there is no need to do anything further.
This system utilises an intelligent flushing system, only the fill time needs
to be determined. The flush frequency is automatically altered dependent
on occupancy. There is also an automatic non-occupancy flush.
After 50 seconds the unit is fully operational.
Note: Switch No1 should now be in the OFF position (DOWN).
Switch No2 has no function and can be left in any position.
The 2 DIL system has a test facility, by inserting a paper clip
through the small hole in the face a test switch is activated.
If the test switch is depressed and released, the circuit board is checked
and the solenoid valve is briefly operated, if the valve opens and closes
this indicates a fully operational unit.
4 DIL Switch Controls—Setting flush interval
Set the required occupancy and non-occupancy flush period on the 4 DIL
switch as shown. After 50 seconds the unit is fully operational.
For further assistance or advice contact us and a technical advisor will help
you:
Tel: 0844 324 0844 info@aqualogic-wc.com
Hydrocell Pre-2006 - Continued
Above example: 20 min flush
delay, 12 hr Hygiene flush