Attention Installer
NOTICE: Read all instructions before installation.
Unit is Pre-wired for 230 only!
IF 208 VOLTS, PLEASE FOLLOW THE INSTRUCTIONS BELOW:
208VOLT/230V WIRING INSTRUCTIONS
ALL INSTALLATION AND WORK MUST BE PERFORMED BY A CERTIFIED ELECTRICIAN AND
PER ALL LOCAL BUILDING AND ELECTRICAL CODES.
WARNING: Before hooking up power to the main contactor, make sure the proper connections have
been made to match the supply voltage on the supplied transformer. Using a voltmeter determine what
the incoming voltage is. If 208V supply is being used, disconnect the factory lead (1) and reconnect it on
(2) as noted in the pictures below. Failure to do so will result in voiding warranty, damage to the unit,
fire, injury, or possibly even death.
Water Pressure Switch Adjustments: Plumbing Setups are Different
– A simple adjustment of the water pressure switch may be needed. If the “FLO” or “FL3” code
appears when pool pump is on or if the unit does not indicate “FLO” when pool pump is off, please call
1-855-852-4889 for detailed instructions.
FIELD WIRING: NOTICE: To aid in field wiring, see the Figure 1 below. Incoming
power is to be connected to L1 and L2 as shown. To insure proper connections tighten the screws
securely to 40-45 in-lbs (4.5-5 N-m). After L1 & L2 Lugs are torqued, move wire side to side to settle
wire strands, then torque again. Failure to do so may result in wires becoming loose which can result in
voiding warranty, damage to the unit, fire, injury, or death.
Bonding & Grounding the Unit are Required.
Failure to do so will result in voiding warranty, damage to the unit, fire, injury, or possibly even death.
Notice: Please remove these instruction from the Electrical area and store with proof of purchase.