Do you have a question about the Argo Clima AWR512CL and is the answer not in the manual?
Cooling Capacity | 12000 BTU/h |
---|---|
Heating Capacity | 13000 BTU/h |
Energy Efficiency Ratio (EER) | 3.21 |
Power Supply | 220-240V, 50Hz |
Noise Level (Indoor) | 42 dB(A) |
Noise Level (Outdoor) | 52 dB(A) |
Refrigerant | R410A |
Operating Temperature (Heating) | 0-30°C |
Weight (Indoor Unit) | 9 kg |
Type | Split Type |
Dimensions (Outdoor Unit) | 700 x 540 x 255 mm |
Emphasizes reading instructions, seeking help, and understanding manufacturer responsibilities before installation or service.
Details critical warnings for wiring, transporting, installation, and servicing procedures to ensure user and system safety.
Details specifications for the AWR512CL indoor unit and AER524DC outdoor unit, including performance and electrical data.
Details specifications for the FCR512CL indoor unit and AER524DC outdoor unit, including performance and electrical data.
Lists specifications for the compressor, fan motor, and heat exchanger coil of the outdoor unit.
Details PCB, controls, fan motor, flap motor, and heat exchanger coil for the AWR512CL indoor unit.
Details PCB, fan motor, flap motor, and other components for the FCR512CL indoor unit.
Provides detailed diagrams and measurements for the outdoor unit's physical size and features.
Provides detailed diagrams and measurements for the AWR512CL indoor unit's physical size and features.
Provides detailed diagrams and measurements for the FCR512CL indoor unit's physical size and features.
Illustrates the path of refrigerant through the indoor and outdoor units of the multi-split system.
Details electrical characteristics, including running amps and power input for the units.
Presents the electric wiring diagram for the outdoor unit, showing connections and components.
Presents the electric wiring diagrams for the indoor units, showing connections and components.
Displays charts showing operating current and pressure versus temperatures.
Guides on selecting an appropriate installation site, considering tubing length and elevation.
Provides safety precautions, general guidelines, and the overall system wiring diagram.
Details the composition, characteristics, and handling precautions for R407C refrigerant.
Lists essential checks and precautions before servicing R407C systems.
Specifies necessary tools for R407C servicing, including specialized and common types.
Covers procedures for installing tubing, including sealing flare portions.
Addresses compressor issues, including replacement, evacuation, and recharging procedures.
Guides on detecting, recovering, welding, and repairing refrigerant leaks.
Explains charging additional refrigerant for extended tubing and retro-fitting systems.
Explains room temperature regulation via compressor cycling and time delays.
Describes the dehumidification function and its operating modes based on room temperature.
Details the freeze prevention mechanism for the indoor heat exchange coil.
Covers preliminary checks for power, wiring, and connectors before diagnosing issues.
Diagnoses reasons for unit non-operation, including circuit breaker trips, ground faults, and power supply issues.
Addresses problems with specific components like the fan or compressor not running.
Provides solutions for performance issues like poor cooling or excessive cooling.
Illustrates the physical placement and identification of electrical parts within the outdoor unit.
Details measuring insulation resistance of electrical parts and wiring for safety.
Explains testing motor capacitors for proper function using a multimeter.
Covers safety precautions and steps for removing the indoor unit air intake grille.
Details removing side panels and accessing the indoor unit's electrical component box.
Explains removing the flap motor and the indoor heat exchange coil.
Provides instructions for safely removing the fan and fan motor assembly.