Checking For Leaks
1. Make a leak check solution by mixing 1 part
dishwashing soap with 3 parts water in a
spray bottle.
2. Make sure the control knob on the fireplace is in
the “OFF” position, then connect your fireplace
to the gas supply line and turn the gas on.
3. Spray the leak solution on the valve connections,
paying particular attention to the areas
indicated by arrows in the diagrams.
4. If bubbles appear, shut off the gas supply,
disconnect the hose and inspect all connections
making sure threads are clear of debris.
Reconnect the hose, turn the gas supply on
and retest. If you continue to see bubbles,
turn the gas supply off, disconnect the hose.
5. If no bubbles appear after 1 minute, wipe
away excess leak solution and proceed to
“Lighting Instructions.”
Wall
Conversion Plaque
Using a wire cutters remove the French NG conversion plaque that is hanging from
the control panel. Use the included cable kit to string both the French and English
NG conversion plaques together and reattach them to the control panel.