Training manual ALTEAS X and GENUS X
Pag. 46 di 84
5.4 BURNER
The same 19.0 mm pitch Polidoro burner is used on all the models. The electrodes (two ignition and one for
flame detection) are constituted by one part. The ignition electrodes have to be kept a t a 4±1mm distance
from the burner 8±1mm ramp. The detection electrode must be at least 8±1mm away from the burner. Any
missed ignition of the burner after the safety time is displayed on the control panel with code 5 01.
The minimum ionisation current is equal to 1microAmp. The ionisation voltage on the ground is equal to
110Vac.
DIAMETER OF THE NOZZLES
Number
G20
G30
G31
24 kW CF
13
1,25 mm
0,76 mm
0,76 mm
30 kW CF
15
1,25 mm
0,75 mm
0,75 mm
24 kW FF
11
1,32 mm
0,80 mm
0,80 mm
30 kW FF
13
1,32 mm
0,80 mm
0,80 mm
32 kW FF
16
1,32 mm
0,78 mm
0,78 mm
35 kW FF
16
1,32 mm
0,78 mm
0,78 mm