4. Insert the cable through channel A (Fig 4) for side entry, after breaking plastic wall and clean
burrs ‘B (Fig. 4) .
5. Connect the cable to terminal block and fully tighten them as follow.
BROWN or RED for LIVE (L)
BLUE or BLACK for NEUTRAL(N)
GREEN or GREEN/YEOLLOW for EARTH(E)
6. Make sure the wiring connection is tight, then close the front cover.
7. Fix back the screw A.
OPERATING INSTRUCTIONS
TO TAKE THE SHOWER FOR THE USER
IMPORTANT!
THE HEATER TANK MUST BE FILLED UP WITH WATER BEFORE TURN ON THE ELECTRIC SUPPLY THIS
IS TO PREVENT ANY DRY BURNT DAMAGE TO THE HEATING ELEMENT.
SHOULD TURN OFF THE HEATER BEFORE TURN OFF THE Product water supply valve.
Starting
1. Turn on the main product water supply valve.
2. Switch on the electric supply on the main switch out of the shower:
a. It enables the SAFETY CHECK technology to run a system scan of the product for 4 sec. and
the SAFETY CHECK led will blink:
i. If everything is running smoothly and safely the SAFETYCHECK and ELCB led will be steady.
ii. If the SAFETY CHECK led continues to blink, it is because SAFETY CHECK technology has de-
tected some failure and the user has to switch o the main supply and contact the service
agent for repair.
3. Turn on the product water supply valve on the product to clockwise until the water ow through
the shower head.
4. Rotate the control knob, the HEATING led will light up and hot water will start owing from the
shower head.
5. Adjust the shower condition setting by:
a. Rotate the control knob in clockwise to increase the temperature or in anticlockwise to de-
crease the temperature;
b. Turn the product water supply valve in clockwise to increase the water ow decreasing the
outlet water temperature or turn it in anticlockwise to decrease water ow increasing the
outlet water temperature;
c. In rare case if inlet water is too cold, both options can be not enough to reach the desired
shower conditions.
6. Temperature setting (g. 2)
4AURES PREMIUM
a. Rotating the control knob the user gradually regulates the Power setting to nd the desired
shower condition:
i. Rotating clockwise the control knob the power gradually increases and the shower tem-
perature will go up., at “MAX” position the hottest outlet water;
ii. Rotating anticlockwise the control knob the power gradually decreases and the shower