MAINTENANCE
ELCB TEST
(only for ELCB models g. 2)
The built-in ELCB function will self-check every time before working, when the user turns “on” the
electricity on the main switch out of the shower and the ELCB led will light up.
It is recommended test at least once a month the correct ELCB functioning.
• After turn on the electricity and water supply:
1. Press the “TEST” button;
2. ELCB led and SAFETY CHECK led will go o,
3. Press the “RESET” button to resume back the power supply,
If the ELCB led blinks and SAFETY CHECK led blinks or ELCB led does not light up and SAFETY CHECK
blinks when the user presses the RESET button, the user has to switches o the main supply and
contact the service agent for repair. NEVER try to repair the unit by yoursel.
NOTA: TESTING THE ELCB REGULARLY
Cleaning precaution
Do not use thinner, alcohol, petrol or any other organic solution to clean the set, use only a damp
cloth with mild detergent.
Cleaning the lter regularly
There are two lters located at the water supply valve, one is mesh lter (installed at the incoming
water supply); the other one is the built-in lter as shown in g.5.
Clean the two lters regularly to prevent blockage. Remove the built-in lter by turning it anti clock-
wise as shown in g.5 B1. Take out the lter and ush it with water to remove any trapped sedi-
ments, as shown in g.5 B2 - B3.
Note: the specication, actual product’s cosmetic design and accessories parts shown are correct at
the time of printing and may be subjected to change without prior notice.