EasyManua.ls Logo

Ariston AURES TOP 4.5P - Troubleshooting

Ariston AURES TOP 4.5P
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 9
EN
Troubleshooting
PROBLEM
SCREEN
DISPLAY
ELCB
LAMP
HEATING
LAMP CHECKING ACTIONS
Cold Water
no temperature
increase
OFF OFF OFF
1. Ensure power supplier availability, by checking
house power supply voltage;.
ON ON OFF
1. Ensure water ow rate is big enough (over 1,2L/
min);
2. Ensure the water heater is turned ON, by rby
pressing ON/OFF button;
3. Ensure product is not in cold water model;
4. Ensure water pipe connection (inlet on right, out
-
let on left). g 5
ON ON ON
Ensure water ow rate is not too big (over 6L/min),
by reducing the ow rate through water supply
valve;
ON OFF OFF
Ensure TEST button is not wrongly pressed, press
the “reset button to light ON the ELCB lamp.
display "E*" ON OFF Stop use the water heater, call service.
-- Blinking -- Stop use the water heater, call service.
Water temp
increased,
but not warm
enough
ON ON ON
1. Increase temperature/power setting.
2. Ensure the water ow rate is not too big (over 6L/
min), by water supply valve; if ow rate too big,
outlet water will not able to reach the setting
temperature;
3. Measure the actual voltage WHEN heating to
make sure voltage drop not too big. By increase
section, or reduce length of the power supply ca
-
ble could improve.
4. Ensure power supplier voltage not too small, by
checking house power supply WITHOUT heating.
Flow rate
too small
-- -- --
1. Ensure the water pressure is big enough to pro-
vide comfortable water ow rate.
2. Ensure there are no dirty, by clean the lter, which
is built in the water supply valve. Fig. 5, B1-B2-B3
3. Ensure there are no bottleneck in the inlet pipe
between water heater to the main water supply
point;
House light
ickering when
heating
ON ON ON
Measuring the actual voltage WHEN heating to
make sure voltage drop not too big. (Voltage drop
should be less than 10%).
By increase section, or reduce length of the power
supply cable could solve the ickering problem.

Related product manuals